Blower Motor Controller Inspection

  1. Remove blower motor controller (2) from HVAC unit (1).
  2. Connect bulb (12 V/5 W) (4) between battery positive terminal and terminal "3", and connect battery negative terminal to terminal "1".
  3. Check for bulb turns on, when connecting dry cell (5) between terminal "2" and battery negative terminal as follows.

    If check result is not satisfactory, replace blower motor controller.

    NOTE: Make sure that the total voltage of dry cell is more than 4.5 V.
    Fig 1: Identifying Blower Motor Controller And HVAC Unit
    G06526724Courtesy of SUZUKI OF AMERICA CORP.