Water Pump Removal and Installation: Installation
Reference: WATER PUMP INSPECTION
Reverse removal procedure noting the following points:
- Use new gasket and O-ring.
- Tighten water pump bolts to specified torque.
Tightening torque
Water pump bolt (a): 25 N.m (2.5 kg-m, 18.5 lbf-ft)
- Refill cooling system, see COOLING SYSTEM REFILLING .