Evaporator Temperature Sensor Inspection
Reference: EVAPORATOR REMOVAL AND INSTALLATION
- Measure resistance between terminals of evaporator temperature sensor.
- Check that the resistance decreases as temperature rises as shown in the illustration.
If check result is not as specified, replace evaporator temperature sensor.
Evaporator temperature sensor resistance
0 °C (32 °F): 6.65 - 6.84 kΩ
25 °C (77 °F): 2.00 - 2.14 kΩ