Air Flow Control Actuator Inspection
Reference: AIR FLOW CONTROL ACTUATOR REMOVAL AND INSTALLATION
- Set arm to actuator and check if arm operates smoothly when battery voltage is conducted to terminals of actuator connector (1).
- Using ohmmeter, measure resistance between "3" terminal and "5" terminal of actuator connector (1) at each arm position.
Air flow control actuator resistance
RESISTANCE REFERENCEArm position Resistance (25 °C (77 °F)) FACE [a] Approx. 5.38 kΩ B/L [b] Approx. 4.32 kΩ FOOT [c] Approx. 2.98 kΩ D/F1 [d] Approx. 2.33 kΩ D/F2 [e] Approx. 1.78 kΩ DFR [f] Approx. 0.62 kΩ - Using ohmmeter, measure resistance between "4" terminal and "5" terminal of actuator connector.
Air flow control actuator resistance (Total resistance) 6 kΩ
If check result is not as specified, replace air flow control actuator.