A/C Switch, Air Flow Selector (Defroster Switch) and Air Intake Selector Inspection

WARNING: This page is about a different car, the 2011 Suzuki SX4. However, it is still accessible from the selected car via links, so may be relevant.

Check that the voltage between the following terminals and body ground are specifications under each conditions.

If check result does not meet the specified value, replace HVAC control unit.

HVAC CONTROL UNIT SPECIFICATIONS

Part Circuit Terminal Specification Condition
A/C switch A/C switch signal circuit 5 Approx. 0 V Ignition switch: "ON" position.
Blower speed selector: "1, 2, 3 or 4" position. A/C switch: "ON" position.
Air flow selector (defroster switch) Air flow selector (defroster switch) signal circuit 5 Approx. 0 V Ignition switch: "ON" position.
Blower speed selector: "1, 2, 3 or 4" position.
Air flow selector: "DEF" or/and "DEF/FOOT" position.
10
Air intake selector Air intake selector ("FRE") circuit 10 Approx. 0 V Ignition switch: "ON" position.
Air intake selector: "FRE" position.
13 Approx. 12 V
Air intake selector ("REC") circuit 13 Approx. 0 V Ignition switch: "ON" position.
Air intake selector: "REC" position.
10 Approx. 12 V
Fig 1: Checking A/C Switch, Air Flow Selector (Defroster Switch) And Air Intake Selector Voltage