A/C Refrigerant Pressure Sensor Removal and Installation: Installation
Reverse removal procedure noting the following instructions:
- Apply compressor oil to O-ring of A/C refrigerant pressure sensor.
- Tighten A/C refrigerant pressure sensor to specified torque.
Tightening torque
A/C refrigerant pressure sensor (a): 11 N.m (1.1 kg-m, 8.0 lbf-ft)
- Evacuate and charge the A/C system referring to "EVACUATION " and "CHARGE " in OPERATION PROCEDURE FOR REFRIGERANT CHARGE: MANUAL A/C.