Removal of Manifold Gauge Set

WARNING: This page is about a different car, the 2011 Suzuki SX4. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: If the manifold gauge set is removed carelessly, refrigerant under pressure may spray out of the high-pressure side of the A/C system. The refrigerant could contact your eyes or skin, causing injury. Remove the manifold gauge set carefully, following the instructions provided below.

For the A/C system charged with the specified amount of refrigerant, remove manifold gauge set as follows:

  1. Close low pressure side valve of manifold gauge set. (The high pressure side valve is closed continuously during the process of charging.)
  2. Close refrigerant container valve.
  3. Stop engine.
  4. Using shop rag, remove charging hoses from service valves. This operation must be performed quickly.
  5. Put caps on service valves.