Fail-Safe Table
WARNING: This page is about a different car, the 2011 Suzuki SX4. However, it is still accessible from the selected car via links, so may be relevant.
When any of the following malfunctions (DTCs) is detected, fail-safe mode is activated.
However, when HVAC control module judges A/C system recovered, fail-safe mode is canceled.
FAIL SAFE DESCRIPTION CHART
| DTC No. | Trouble Area | Fail-Safe Operation | |
|---|---|---|---|
| When ignition switch is turned ON after malfunction is already detected | When malfunction is detected during ignition switch is ON | ||
| B1502 | Inside air temperature sensor circuit | HVAC control module maintains last normal value. | HVAC control module controls actuators assuming that inside air temperature is 25 °C (77 °F). |
| B1503 | A/C evaporator temperature sensor circuit | HVAC control module assuming that evaporator temperature is 0 °C (32 °F). |
|
| B1504 | Sunload sensor circuit | HVAC control module maintains last normal value. | HVAC control module controls actuators assuming that amount of sunlight is 0 W/m2 . |
| B1551 | Serial communication circuit |
|
HVAC control module controls actuators assuming that outside air temperature is 20 °C (68 °F), engine coolant temperature is 80 °C (176 °F), vehicle speed is 40 km/h (25 mph), engine type signal is J20 and combination meter spec signal is US. |
| B1552 | HVAC control module check sum error | ||
| B1553 | CAN communication circuit | ||
| B1557 | VSS signal failure | HVAC control module controls actuators assuming that vehicle speed is 40 km/h (25 mph). | |
| B1561 | ECT signal failure | HVAC control module maintains last normal value of engine coolant temperature. 4 seconds after, HVAC control module assuming that engine coolant temperature is 80 °C (176 °F). | HVAC control module controls actuators assuming that engine coolant temperature is 80 °C (176 °F). |
| B1562 | Outside air temperature signal failure | HVAC control module maintains last normal value of outside air temperature. 4 seconds after, HVAC control module assuming that outside air temperature is 20 °C (68 °F). |
HVAC control module controls actuators assuming that outside air temperature is 20 °C (68 °F). |
| B1570 | Engine type signal failure | HVAC control module controls actuators assuming that engine type signal is J20. | |
| B1571 | Combination meter spec signal failure | HVAC control module controls actuators assuming that combination meter spec signal is US. | |