  1. Measure resistance between connector terminals at both ends of the circuit being checked (between "A-1" and "C-1" in the figure). If no continuity is indicated (infinity or over limit), that means that the circuit is open between terminals "A-1" and "C-1".
    Fig 1: Measuring Resistance Between Connector Terminals
    G06868148Courtesy of SUZUKI OF AMERICA CORP.
  2. Disconnect the connector included in the circuit (connector-B in the figure) and measure resistance between terminals "A-1" and "B-1".

    If no continuity is indicated, that means that the circuit is open between terminals "A-1" and "B-1". If continuity is indicated, there is an open circuit between terminals "B-1" and "C-1" or an abnormality in connector-B.

    Fig 2: Measuring Resistance Between Terminals "A-1" And "B-1"
    G06868149Courtesy of SUZUKI OF AMERICA CORP.