Thermostat Removal and Installation: Installation
Reference: THERMOSTAT INSPECTION
Reverse removal procedure for installation noting the following points.
- When positioning thermostat (1) on water pump case, be sure to position it so that air bleed valve (2) is aligned with match mark (3).
- Use new gasket when installing thermostat.
- Refill cooling system, see COOLING SYSTEM REFILLING .
- Verify that there is no coolant leakage at each connection, see ENGINE COOLING SYSTEM INSPECTION .