LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2012 >> Kizashi AWD L4-2.4L >> Repair and Diagnosis >> Heating and Air Conditioning >> Blower Motor Resistor >> Service and Repair >> Blower Motor Controller Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Blower Motor Controller Inspection




Blower Motor Controller Inspection

1) Remove blower motor controller (2) from HVAC unit (1).
2) Connect bulb (12 V/5 W) (4) between battery positive terminal and terminal "3", and connect battery negative terminal to terminal "1".
3) Check if bulb turns on, when connecting dry cell (5) between terminal "2" and battery negative terminal as follows.

If check result is not satisfactory, replace blower motor controller.

NOTE:
Make sure that the total voltage of dry cell is more than 4.5 V.