A-BAG Branch Line Circuit Check
WARNING:
Always observe the following items for preventing accidental activation.
- Before servicing, turn ignition switch OFF, disconnect battery negative terminal, and wait 3 minutes or more. (To discharge backup capacitor.)
- Never use unspecified tester or other measuring device.
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK CONNECTOR
Is the inspection result normal? |
GO TO 2. | Replace the main harness. |
| 2 | CHECK AIR BAG DIAGNOSIS SENSOR UNIT Check the air bag diagnosis sensor unit. Refer to [Diagnosis and Repair Workflow: Interview Sheet ]. Is the inspection result normal? |
Replace the main harness. | Replace parts whose air bag system has a malfunction. |