With SDT
- Turn ignition switch ON and select "Data list" mode with SDT.
- Make sure the following conditions are met.
FUEL LEVEL SE: 0.25 - 1.4V
COOLAN TEMP/S: 0 - 32 °C (32 - 90 °F)
FUEL T/TMP SE: 0 - 35 °C (32 - 95 °F)
INT/A TEMP SE: More than 0 °C (32 °F)
If NG, turn ignition switch OFF and leave the vehicle in a cool place (soak the vehicle), or refill/drain fuel until the output voltage of the "FUEL LEVEL SE" meets within the range above and leave the vehicle for more than 1 hour. Then start from step 1.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON.
- Select "EVAP V/S LEAK P0456/P1456" of "EVAPORATIVE SYSTEM" in "DTC work support" mode with SDT.
Follow the instructions displayed.
- Make sure that "OK" is displayed.
If "NG" is displayed, refer to [Diagnosis Procedure ].
NOTE:- If the engine speed cannot be maintained within the range displayed on SDT screen, go to [BASIC INSPECTION ].
- Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve properly.