Crankshaft Main Journal Diameter
- Measure the outer diameter of crankshaft main journals with a micrometer.
Standard: 54.955 - 54.979 mm (2.1636 - 2.1645 in) dia.
- If out of the standard, measure the main bearing oil clearance. Then use undersize bearing. Refer to [SERVICE DATA AND SPECIFICATIONS ].