Interior Lighting System Symptoms: Symptom Table [With Power Door Locks]
CAUTION:
Perform "DTC check" with SDT before the symptom diagnosis. Perform the trouble diagnosis if any DTC is detected.
SYMPTOM CHART
| Symptom | Possible cause | Inspection item |
|---|---|---|
All of the following lamps do not turn ON
|
|
Battery saver output/power supply circuit Refer to Battery Saver Output/Power Supply Circuit Check [with Power Door Locks] . |
Some or all of the following interior room lamps do not turn ON/OFF
|
|
Interior room lamp control circuit Refer to Interior Lamp Control Circuit Check [with Power Door Locks] . |
| Cargo lamp does not turn ON/OFF |
|
Cargo lamp control circuit Refer to Cargo Lamp Control Circuit Check [with Power Door Locks] . |
| Ignition keyhole illumination does not turn ON/OFF |
|
Ignition keyhole illumination circuit Refer to Ignition Keyhole Illumination Control Circuit Check [with Power Door Locks] |
| Interior room lamp timer does not activate. (It turns ON/OFF when the door opens/closes.) |
- | Check the interior room lamp setting. Refer to SDT Function (BCM - INT LAMP) [With Power Door Locks] . |
| Interior room lamp battery saver does not activate. | - | Check the interior room lamp battery saver setting. |