Starting Motor Inspection: Armature
- Check commutator for dirt or burn. Correct commutator with sandpaper or lathe, if necessary.
- Check commutator for uneven wear with armature (1) supported on V-blocks (2). If dial gauge (4) deflects exceeding the limit, repair commutator or replace armature.
Commutator out of round
Standard: 0.05 mm (0.002 in.) or less
Limit: 0.4 mm (0.02 in.)
- Check commutator for wear. If diameter is below limit, replace armature.
Commutator outside diameter
Standard: 29.4 mm (1.16 in.)
Limit: 28.8 mm (1.14 in.)
- Check commutator (1) for insulator (2) depth. Correct insulator depth or replace commutator if measurement is below limit.
Commutator insulator depth "a"
Standard: 0.5 mm (0.020 in)
Limit: 0.2 mm (0.008 in.)
- Check insulation between commutator and armature core. If there is continuity, armature is grounded and must be replaced.
- Check for continuity between segments. If there is no continuity at any test point, there is an open circuit and armature must be replaced.