LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2011 >> Grand Vitara Limited, RWD >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System Diagnosis >> Diagnostic Information and Procedures >> DTC P2400: Evaporative Emission System Leak Detection Pump Control Circuit / Open >> DTC Troubleshooting
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC Troubleshooting

DIAGNOSIS PROCEDURE

Step Action YES NO
Was "Engine and Emission Control System Check" performed?  Go to Step 2. Go to ENGINE AND EMISSION CONTROL SYSTEM CHECK:J24B .
EVAP leak detection pump operation check 
  1. Check operating sound of EVAP leak detection pump referring to "EVAP Leak Detection Pump Circuit Check" under EVAP LEAK CHECK MODULE CIRCUIT INSPECTION .

Is operating sound heard? 
Go to Step 4. Go to Step 3.
Detection pump circuit check 
  1. Turn OFF ignition switch and disconnect connectors from EVAP leak check module and ECM.
  2. Check for proper terminal connection to EVAP leak check module and ECM connectors.
  3. If connections are OK, check that EVAP leak detection pump drive circuit (C1) and ground circuit (C2) is as follows.
    • Wiring harness resistance of each EVAP leak detection pump drive circuit and ground circuit is less than 3 Ω.
    • Insulation resistance of EVAP leak detection pump drive circuit is infinity between EVAP leak check module connector and vehicle body ground.
    • Insulation resistance of wire harness is infinity between EVAP leak detection pump drive circuit terminal and each terminal at EVAP leak check module connector.
    • Circuit voltage of EVAP leak detection pump drive circuit is 0 - 1 V with ignition switch in ON position.

Are they in good condition? 
Go to Step 4. Repair or replace defective wire harness.
EVAP leak detection pump check 
  1. Check EVAP leak detection pump for operation referring to "EVAP Leak Detection Pump Check" under EVAP LEAK CHECK MODULE CIRCUIT INSPECTION .

Is it in good condition? 
Substitute a known-good ECM and recheck. Replace EVAP leak check module.