IMT Vacuum Solenoid Valve Inspection
WARNING:
If vacuum is applied using your mouth, there is a risk of inhaling harmful fuel vapor. Be sure to use a hand vacuum pump to apply vacuum.
CAUTION:
Do not apply vacuum more than -86 kPa (-0.86 kgf/cm2
, -12.47 psi, -0.86 bar); otherwise IMT vacuum solenoid valve could be damaged.
- With ignition switch turned OFF, disconnect connector and vacuum hoses from IMT vacuum solenoid valve.
- Remove IMT vacuum solenoid valve.
- Check resistance between two terminals of IMT vacuum solenoid valve connector. If faulty condition is found, replace IMT vacuum solenoid valve.
IMT vacuum solenoid valve resistance
27 - 33 Ω at 20 °C (68 °F)
- Check IMT vacuum solenoid valve operation as follows.
If faulty condition is found, replace IMT vacuum solenoid valve.
- Install special tool and vacuum hose (2) to IMT vacuum solenoid valve (1).
Special Tool
(A): 09917-47011
- Operate the special tool and check that vacuum of -60 kPa (-0.6 kgf/cm2 , -8.7 psi, -0.6 bar) can be applied to IMT vacuum solenoid valve when 12 V battery is not connected to IMT vacuum solenoid valve terminals.
- Operate the special tool and check that no vacuum can be applied to IMT vacuum solenoid valve when 12 V battery is connected to IMT vacuum solenoid valve terminals.
- Install special tool and vacuum hose (2) to IMT vacuum solenoid valve (1).