Reference waveform No. 6
CAN communication signal
WAVEFORM 6 REFERENCE
| Measurement terminal | CAN communication signal for each control module CH1: "G31-1" to "G30-12" CH2: "G31-3" to "G30-12" CAN communication signal for DLC CH1: "G31-2" to "G30-12" CH2: "G31-4" to "G30-12" |
| Oscilloscope setting | CH1: 1 V/DIV CH2: 1 V/DIV TIME: 40 μs/DIV |
| Measurement condition | Ignition switch is at ON position |