Diagnosis Procedure
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
Is the inspection result normal? |
GO TO 2 | GO TO 4 |
| 2 | REMOTE KEYLESS ENTRY RECEIVER 5-VOLT CIRCUIT INSPECTION Check voltage between remote keyless entry receiver connector M120 terminal 4 and ground. 4 - Ground: Approx. 5 volt. Is the inspection result normal? |
GO TO 3 | GO TO 4 |
| 3 | REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT INSPECTION Check continuity between remote keyless entry receiver connector M120 terminal 1 and ground. 1 - Ground: Continuity should exist. Is the inspection result normal? |
Replace remote keyless entry receiver. | GO TO 4 |
| 4 | HARNESS INSPECTION BETWEEN BCM AND RKE RECEIVER
1 - 18: Continuity should exist. 2 - 20: Continuity should exist. 4 - 19: Continuity should exist.
Is the inspection result normal? |
Replace remote keyless entry receiver. | Repair or replace the harness between the remote keyless entry receiver and BCM. |