Expansion Valve: Removal and Installation: Installation
Installation is in the reverse order of removal.
CAUTION:
- Do not reuse O-rings.
- Apply A/C oil to the expansion valve O-rings and the A/C refrigerant pipe O-rings for installation.
- After charging refrigerant, check for leaks.
Front expansion valve bolts : 4.0 N.m (0.41 kg-m, 35 in-lb)
A/C refrigerant pipe to front expansion valve bolt : 3.4 N.m (0.35 kg-m, 30 in-lb)