Diagnosis Procedure
Regarding Wiring Diagram information, refer to [CHARGING SYSTEM: WIRING DIAGRAM ].
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK VOLTAGE REGULATOR CIRCUIT CONNECTION Check to see if connector E205 terminal 3 is clean and tight. Is the inspection result normal? |
GO TO 2 | Repair terminal connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin. |
| 2 | CHECK VOLTAGE REGULATOR CIRCUIT Check voltage between generator harness connector E205 terminal 3 and ground. 3 - ground Battery voltage Does battery voltage exist? |
Refer to [DIAGNOSIS AND REPAIR WORKFLOW ]. | Check harness for open between generator and fuse. |