Diagnosis Procedure
Regarding Wiring Diagram information, refer to [CHARGING SYSTEM: WIRING DIAGRAM ].
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK CHARGE WARNING LAMP CIRCUIT CONNECTION Verify generator connector E205 terminal 2 is clean and tight. Is the connection secure? |
GO TO 2 | Repair the connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin. |
| 2 | CHECK CHARGE WARNING LAMP CIRCUIT
Charge lamp should illuminate Does the charge lamp illuminate? |
Check generator function. Refer to [DIAGNOSIS AND REPAIR WORKFLOW ]. | GO TO 3 |
| 3 | CHECK HARNESS CONTINUITY
Are the continuity results as specified? |
Replace the combination meter. Refer to [COMBINATION METER: REMOVAL AND INSTALLATION ] | Repair the harness or connector. |