Diagnosis Procedure

Regarding Wiring Diagram information, refer to [CHARGING SYSTEM: WIRING DIAGRAM ].

DIAGNOSIS PROCEDURE

Step Action YES NO
CHECK CHARGE WARNING LAMP CIRCUIT CONNECTION 
Verify generator connector E205 terminal 2 is clean and tight.
Is the connection secure? 
GO TO 2 Repair the connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin.
CHECK CHARGE WARNING LAMP CIRCUIT 
  1. Disconnect generator connector E205.
  2. Apply ground to generator harness connector E205 terminal 2 with the ignition switch in the ON position.
G06444645Courtesy of SUZUKI OF AMERICA CORP.

Charge lamp should illuminate 
Does the charge lamp illuminate? 
Check generator function. Refer to [DIAGNOSIS AND REPAIR WORKFLOW ]. GO TO 3
CHECK HARNESS CONTINUITY 
  1. Turn ignition switch OFF.
G06444646G06444647G06444648Courtesy of SUZUKI OF AMERICA CORP.SUZUKI OF AMERICA CORP.SUZUKI OF AMERICA CORP.

  1. 2. Disconnect the combination meter connector M24.
  2. 3. Check continuity between generator harness connector E205 (A) terminal 2 and combination meter harness connector M24 (B) terminal 2.
G06444646G06444647G06444648Courtesy of SUZUKI OF AMERICA CORP.SUZUKI OF AMERICA CORP.SUZUKI OF AMERICA CORP.

  1. 4. Check continuity between generator harness connector E205 (A) terminal 2 and ground.
G06444646G06444647G06444648Courtesy of SUZUKI OF AMERICA CORP.SUZUKI OF AMERICA CORP.SUZUKI OF AMERICA CORP.

Are the continuity results as specified? 
Replace the combination meter. Refer to [COMBINATION METER: REMOVAL AND INSTALLATION ] Repair the harness or connector.