Diagnosis Procedure
Regarding Wiring Diagram information, refer to [CHARGING SYSTEM: WIRING DIAGRAM ].
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK TERMINAL "1" CONNECTION
Is the inspection result normal? |
GO TO 2 | Repair terminal "1" connection. Confirm repair by performing complete Starting/Charging system test. Refer to Technical Service Bulletin. |
| 2 | CHECK TERMINAL "1" CIRCUIT Check voltage between generator connector E206 terminal 1 and ground. Is voltage reading as specified? |
GO TO 3. | Check harness for open between generator and fusible link. |
| 3 | CHECK TERMINAL "1" CONNECTION (VOLTAGE DROP TEST)
Is the voltage reading as specified? |
Terminal "1" circuit is normal. Refer to [DIAGNOSIS AND REPAIR WORKFLOW ]. | Check harness between battery and generator for high resistance. |