Diagnosis Procedure
Regarding Wiring Diagram information, refer to [POWER DOOR LOCK SYSTEM: WIRING DIAGRAM [KING CAB] ].
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL With SDT Check door lock/unlock switch ("CDL LOCK SW", "CDL UNLOCK SW") in "Data list" mode in SDT. Refer to [SDT FUNCTION (BCM - DOOR LOCK) ].
Without SDT
Is the inspection result normal? |
Door lock and unlock switch circuit is OK. | GO TO 2 |
| 2 | CHECK BCM OUTPUT SIGNAL Check ("POWER WINDOW DOWN") in "Active test" mode for "MULTI REMOTE ENT" with SDT. Refer to [SDT FUNCTION (BCM - DOOR LOCK) ]. When "Active test" is performed, are the front windows lowered? Is the inspection result normal? |
GO TO 3 | Replace BCM. Refer to [BCM (BODY CONTROL MODULE): REMOVAL AND INSTALLATION ] |
| 3 | CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS
15 - Ground: Continuity should exist
11 - Ground: Continuity should exist Is the inspection result normal? |
GO TO 4 | Repair or replace harness. |
| 4 | CHECK POWER WINDOW SERIAL LINK CIRCUIT
22 - 16: Continuity should exist
22 - Ground: Continuity should not exist Is the inspection result normal? |
Replace main power window and door lock/unlock switch or power window and door lock/unlock switch RH. | Repair or replace harness. |