IMT Valve Actuator Inspection
CAUTION:
Be sure not to apply battery voltage to IMT valve actuator for 10 seconds or more.
Connect battery positive (+) and negative (-) terminals to IMT valve actuator (2) as shown in table below. If IMT valve actuator pinion gear (1) does not operate as specified direction, replace IMT valve actuator, see IMT VALVE ACTUATOR REMOVAL AND INSTALLATION .
IMT valve actuator pinion gear rotative direction
IMT VALVE ACTUATOR TERMINAL REFERENCE
| Rotative direction | Terminal | |
|---|---|---|
| "1" | "2" | |
| Clockwise | + | - |
| Counterclockwise | - | + |