ECM Power Supply Circuit Monitor
OPERATION
| DTC(s) | P0562, P0563 |
| Monitor execution | Continuous |
| Monitoring Duration | 0.5 sec. |
ENABLE CONDITIONS
| Parameter | Min. | Max. |
|---|---|---|
| P0562: | ||
| Time after engine start | 60 sec. | - |
| P0563: | ||
| Time after engine start | 60 sec. | - |
| Vehicle speed | 2.5 km/h (1.5 mph) | - |
| VSS | No DTC (P0500, P0501) | |
TYPICAL MALFUNCTION THRESHOLDS
| P0562: |
| Battery voltage < 10 V |
| P0563: |
| Battery voltage > 18 V |