LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Suzuki >> 2010 >> Grand Vitara Base, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Engine General Information And Diagnosis (N32A)) >> General Description >> OBD System Description - EVAP Control System Monitor >> EVAP System Large Leak Monitor >> Notes
April 5, 2026: LEMON Manuals is launched! Read the announcement.

EVAP System Large Leak Monitor: Notes

WARNING: This page is about a different variant/trim than selected.
OPERATION

DTC(s) P0455
Monitor execution Once per driving cycle (Quantity of incomplete tests, up to 10 test attempts will be made in a given driving cycle.)
Monitoring Duration < 30 sec.
ENABLE CONDITIONS

Parameter Min. Max.
Fuel system status Closed loop
Vehicle speed - 3.1 km/h (1.9 mph)
Accelerator pedal position = 0%
Battery voltage 10.5 V 18 V
Ambient temperature 1.5 °C (34.7 °F) 32.3 °C (90.1 °F)
Fuel level 15% 85%
ECT at engine starting 3.75 °C (38.75 °F) 35.25 °C (95.45 °F)
ECT - ambient temperature at engine starting - 9.8 °C (17.6 °F)
Elapsed time from engine starting> 600 sec. or long term fuel trim < 0.03 per 30 sec.
Ambient pressure 68 kPa -
TYPICAL MALFUNCTION THRESHOLDS

P0455: 
Integrated air mass flow > 0.38 - 1.08 g and vacuum pull-down > -700 Pa
or integrated air mass flow > 1.6 g and vacuum pull-down > -800 Pa