Home >> Suzuki >> 2010 >> Grand Vitara Base, Automatic >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Engine General Information And Diagnosis (N32A)) >> General Description >> OBD System Description - Comprehensive Component (Rationality) Monitor >> Fuel Tank Pressure Sensor Rationality Monitor
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Fuel Tank Pressure Sensor Rationality Monitor

WARNING: This page is about a different variant/trim than selected.
OPERATION

DTC P0451
Monitor execution Continuous
Monitoring Duration 10 sec.
ENABLE CONDITIONS

Parameter Min. Max.
Monitor 1: 
Ambient temperature -10.5 °C (13.1 °F) -
Vehicle speed - 30 km/h (19 mph).
Accelerator pedal position = 0%
Monitor 2: 
Accelerator pedal position = 0%
Vehicle speed > 30 km/h (19 mph), its continuous time > 30 sec.
Ambient temperature -10.5 °C (13.1 °F) -
Ambient pressure 68 kPa -
Fuel level 15% 85%
Monitor 3: 
Commanded EVAP purge - 0%
Ambient pressure 68 kPa -
Vehicle speed > 30 km/h (19 mph), its continuous time > 30 sec.
Fuel level 15% 85%
Ambient temperature 1.5 °C (34.7 °F) 32 °C (90 °F)
TYPICAL MALFUNCTION THRESHOLDS

P0451: 
Monitor 1: 
Delta pressure signal (absolute value) (= current pressure - old pressure) > 813 Pa
Monitor 2: 
Sensor signal > 1,500 Pa or < -3,656 Pa
Monitor 3: 
Delta pressure signal (absolute value) (= filtered current pressure - reference pressure at engine starting) > 1000 Pa