Circuit/System Description
The clutch pressure control (PC) solenoid 3 is part of the control solenoid (w/body and TCM) valve assembly and is not serviced separately. The TCM supplies 12 volts to the clutch PC solenoid 3 on the high side driver 1 circuit. The TCM controls the clutch PC solenoid 3 through the clutch PC solenoid 3 control circuit. The normally high clutch PC solenoid 3 flows fluid to the low and reverse clutch and 4-5-6 clutch assemblies when commanded ON and exhausts fluid when commanded OFF. The clutch PC solenoid 3 regulates the transmission fluid pressure to the low and reverse clutch and 4-5-6 clutch assemblies.