Circuit/System Description
The body control module (BCM) receives battery voltage from the CTSY/RF TRN fuse in order to supply power to the courtesy lamps. The BCM applies this voltage to the courtesy lamps through the courtesy lamp supply voltage circuits. When any door is opened, the door open switch contacts close and the BCM receives a door-open signal. If the BCM receives a door lock or unlock signal, the BCM will activate the courtesy lamp supply voltage circuit, providing battery voltage to the dome lamps and the left and right footwell courtesy lamps. The courtesy lamps can be manually activated by placing the interior lamp switch in the DOME position. For more detailed information concerning courtesy lamp operation refer to INTERIOR LIGHTING SYSTEMS DESCRIPTION AND OPERATION .
The BCM receives battery voltage from the INT LAMPS fuse in order to supply power to the inadvertent courtesy lamps. Inadvertent power courtesy lamp feature provides a similar function for the interior lamps as a retained accessory power feature. The BCM will energize the courtesy lamps supply voltage circuit when the BCM is in the active state (awake). When the inadvertent power courtesy lamps supply voltage circuit is energized, it supplies voltage to all the interior lights listed below. The BCM will continue to supply voltage to the interior lamps after the ignition is turned OFF so that the interior lamps may be operated.
In the event that any of these lamps were to remain illuminated for a period of more than 20 minutes with the ignition switch in the OFF position and no BCM input activity, the BCM will deactivate the inadvertent power supply voltage circuit to prevent a total battery discharge condition.