Liftgate Release Switch Malfunction
- Ignition OFF, disconnect the harness connector at the liftgate switch.
- Test for less than 1 ohm between the ground circuit terminal C and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, test for greater than 9 volts between the signal circuit terminal A and ground.
- If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
- Install a 3A fused jumper wire between the signal circuit terminal A and ground. Verify the scan tool Trunk Release Solenoid parameter is On.
- If not the specified value, test the signal circuit for a short to voltage. If the circuit tests normal, replace the BCM.
- If all circuits test normal, test or replace the liftgate release switch.