Component Testing
Door Lock Switch Test
- Ignition OFF, disconnect the harness connector at the appropriate door lock switch.
- Test for infinite resistance between the signal terminals 2 and 1 and the ground terminal 3 with the switch in the open position.
- If not the specified value, replace the door lock switch.
- Test for less than 2 ohms between the signal terminal 1 and the ground terminal 3 with the switch in the LOCK position.
- If greater than the specified range, replace the door lock switch.
- Test for less than 2 ohms between the signal terminal 2 and the ground terminal 3 with the switch in the UNLOCK position.
- If greater than the specified range, replace the door lock switch.
Door Latch
- Ignition OFF, disconnect the harness connector at the appropriate door latch
- Install a 15A fused jumper wire between one of the control terminals and 12 V. Momentarily install a jumper wire between the other control terminal and ground. Reverse the jumper wires at least two times, the door latch should perform the LOCK/ UNLOCK functions.
- If it does not perform as specified, replace the door latch