Circuit/System Testing
- Ignition OFF, disconnect the X4 and X7 harness connectors at the BCM.
- Connect a 10A fused jumper wire between the control circuit terminal 13 and B+. Verify the liftgate latch does not activate.
- If the liftgate latch activates, test the control circuit terminal 22 for a short to ground. If the circuit tests normal replace the I/P fuse block.
- If the fuse in the jumper wire opens, test the control circuit terminal 13 for a short to ground. If the circuit tests normal replace the I/P fuse block.
- If all circuits test normal, replace the BCM.