Side Window Defogger Outlet Duct Replacement - Left Side
Side Window Defogger Outlet Duct Replacement - Left SideRemoval Procedure
1. Remove the instrument panel (I/P) upper trim panel. Refer to [Instrument Panel Upper Trim Panel Replacement].
2. Remove the LH defogger duct screws from the I/P upper trim panel.
3. Remove the LH defogger duct from the I/P upper trim panel.
Installation Procedure
1. Inspect the seals, and replace if damaged, using Kent Industries adhesive backed foam tape P/N 46485 or equivalent.
2. Install the LH defogger duct to the I/P upper trim panel.
CAUTION: Refer to [Fastener Notice] in Cautions and Notices.
3. Install the LH defogger duct screws to the I/P upper trim panel.
Tightening torque
Tighten the screws to 1 N.m (9 lb.in).
4. Install the instrument panel upper trim panel. Refer to [Instrument Panel Upper Trim Panel Replacement].