Resistance Check

WARNING: This page is about a different variant/trim than selected.

Check resistance between pressure control solenoid valve (1) terminals. If check result is not as specified, replace solenoid valve.

Pressure control solenoid valve resistance 

Standard: 3.3 - 3.7 Ω (at 20°C (68°F)) 

Fig 1: Checking Resistance Between Pressure Control Solenoid Valve Terminals
G04847800Courtesy of SUZUKI OF AMERICA CORP.