System Description/Monitoring Procedure
WARNING: This page is about a different variant/trim than selected.
HO2S are used for catalyst monitoring and fuel control system (sub feed back). ECM monitors maximum and minimum voltage, insufficient activity response rates when monitoring conditions are met. If detects malfunction, the ECM will set DTC.