IAT Sensor Circuit Monitor
WARNING: This page is about a different variant/trim than selected.
OPERATION
| DTC(s) | P0112, P0113 |
| Monitor execution | Continuous |
| Monitoring Duration | 5 sec. |
ENABLE CONDITIONS
| Parameter | Min. | Max. |
|---|---|---|
| P0112: | ||
| Not applicable | ||
| P0113: | ||
| Elapsed time from engine starting > 180 sec. and time in idling | 10 sec. | - |
| Fuel system status | No fuel-cut | |
TYPICAL MALFUNCTION THRESHOLDS
| P0112: |
| IAT > 132 °C (269.6 °F) |
| P0113: |
| IAT < -42 °C (-43.6 °F) |