APP Sensor Circuit Monitor
WARNING: This page is about a different variant/trim than selected.
OPERATION
| DTC(s) | Main: P2122, P2123 Sub: P2187, P2188 |
| Monitor execution | Continuous |
| Monitoring Duration | 0.2 sec. |
ENABLE CONDITIONS
| Parameter | Min. | Max. |
|---|---|---|
| Battery voltage | 7 V | - |
TYPICAL MALFUNCTION THRESHOLDS
| P2122: |
| Voltage < 0.684 V |
| P2123: |
| Voltage < 4.8242 V |
| P2127: |
| Voltage < 0.605 V |
| P2128: |
| Voltage < 4.8242 V |