EVAP Leak Detection Pump Check
Reference: EVAP LEAK CHECK MODULE REMOVAL AND INSTALLATION
- Check EVAP leak detection pump in EVAP leak check module as follows.
- Connect a spherical plastic bag (1) with approximately 12.5 cm (4.92 in.) diameter (volume: 1L) to EVAP leak check module using a rubber band (2) as shown in figure.
- Operate EVAP canister vent valve and EVAP leak detection pump by connecting 12 V-battery to EVAP leak check module terminals as shown in figure.
- Check that air in plastic bag is fully evacuated by EVAP leak detection pump within approximately 2 minutes.
If check result is not as described above, replace EVAP leak check module.
CAUTION: Make sure that connection is made between correct terminals. Wrong connection can cause damage to EVAP canister vent valve and EVAP leak detection pump in EVAP leak check module.