No-Load Check
NOTE:
Use fully charged battery.
- Check for DTC.
If there is any DTC, perform trouble shooting for applicable DTC and then clear DTC.
Trouble shooting:
DTC clearance:
- N32A: See DTC CLEARANCE .
- J24B: See DTC CLEARANCE .
- Turn off all electrical loads (5).
- Connect voltmeter (3) and ammeter (2) as shown in figure.
- Start engine and warm it up to normal operating temperature.
- Run engine around 2,000 RPM and read meters.
- If voltage is higher than standard value, check ground circuit of brushes. See GENERATOR INSPECTION .
If brushes are not grounded, replace IC regulator.
- If voltage is lower than standard value, inspect rotor, stator, rectifier, bushes and regulator. See GENERATOR INSPECTION .
Specification for generator test (No-load check)
N32A
Current: 10A
Regulated voltage: 14.2 - 14.8 V (at 25 °C, 77 °F)
J24B
Current: 10A
Regulated voltage: 14.2 - 14.8 V (at 20 °C, 68 °F)
- If voltage is higher than standard value, check ground circuit of brushes. See GENERATOR INSPECTION .