CAN Communication Circuit Check
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CONNECTOR INSPECTION
Is the inspection result normal? |
GO TO 2. | Repair the terminal and connector. |
| 2 | CHECK HARNESS CONTINUITY (SHORT CIRCUIT) Check the continuity between the data link connector terminals. Is the inspection result normal? |
GO TO 3. | Check the harness and repair the root cause. |
| 3 | CHECK HARNESS CONTINUITY (SHORT CIRCUIT) Check the continuity between the data link connector and the ground. Is the inspection result normal? |
GO TO 4. | Check the harness and repair the root cause. |
| 4 | CHECK ECM AND IPDM E/R TERMINATION CIRCUIT
Is the measurement value within the specification? |
GO TO 5. | Replace the ECM and/or the IPDM E/R. |
| 5 | CHECK SYMPTOM Connect all the connectors. Check if the symptoms described in the "Symptom (Results from interview with customer)" are reproduced. Inspection result |
GO TO 6. | Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected. |
| 6 | CHECK UNIT REPRODUCTION Perform the reproduction test as per the following procedure for each unit.
Inspection result |
Connect the connector. Check other units as per the above procedure. | Replace the unit whose connector was disconnected. |