DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK OVERALL FUNCTION
OK or NG |
INSPECTION END | GO TO 2. |
| 2 | CHECK VACUUM EXISTENCE With SDT
OK or NG |
Repair or replace power valve actuator. | GO TO 4. |
| 3 | CHECK VACUUM EXISTENCE Without SDT
OK or NG |
Repair or replace power valve actuator. | GO TO 4. |
| 4 | CHECK VACUUM HOSE
OK or NG |
GO TO 5. | Repair hoses or tubes. |
| 5 | CHECK VACUUM TANK Refer to [VIAS CIRCUIT CHECK ]. OK or NG |
GO TO 6. | Replace vacuum tank. |
| 6 | CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
Voltage: Battery voltage OK or NG |
GO TO 8. | GO TO 7. |
| 7 | DETECT MALFUNCTIONING PART Check the following.
|
Repair harness or connectors. | |
| 8 | CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
OK or NG |
GO TO 9. | Repair open circuit or short to ground or short to power in harness or connectors. |
| 9 | CHECK VIAS CONTROL SOLENOID VALVE Refer to [VIAS CIRCUIT CHECK ]. OK or NG |
GO TO 10. | Replace VIAS control solenoid valve. |
| 10 | CHECK INTERMITTENT INCIDENT Refer to [SERVICE INFORMATION FOR ELECTRICAL INCIDENT: INTERMITTENT INCIDENT ] |
INSPECTION END |