MA Branch Line Circuit Check
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK CONNECTOR
Is the inspection result normal? |
GO TO 2. | Repair the terminal and connector. |
| 2 | CHECK HARNESS FOR OPEN CIRCUIT
Is the measurement value within the specification? |
GO TO 3. | Repair the combination meter branch line. |
| 3 | CHECK POWER SUPPLY AND GROUND CIRCUIT Check the power supply and the ground circuit of the combination meter. Refer to [POWER SUPPLY AND GROUND CIRCUIT CHECK [COMBINATION METER] ] Is the inspection result normal? |
Replace the combination meter. Refer to [COMBINATION METER: REMOVAL AND INSTALLATION ] | Error was detected in the combination meter branch line. |