Diagnosis Procedure
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
Voltage: Battery voltage OK or NG |
GO TO 3. | GO TO 2. |
| 2 | DETECT MALFUNCTIONING PART Check the following.
|
Repair harness or connectors. | |
| 3 | CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
OK or NG |
GO TO 4. | Repair open circuit or short to ground or short to power in harness or connectors. |
| 4 | CHECK VIAS CONTROL SOLENOID VALVE Refer to [P1800 VIAS CONTROL SOLENOID VALVE 1 ]. OK or NG |
GO TO 5. | Replace VIAS control solenoid valve. |
| 5 | CHECK INTERMITTENT INCIDENT Refer to [SERVICE INFORMATION FOR ELECTRICAL INCIDENT: INTERMITTENT INCIDENT ] |
INSPECTION END |