Diagnosis Procedure
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK GROUND CONNECTIONS
OK or NG |
GO TO 2. | Repair or replace ground connections. |
| 2 | CHECK PSP SENSOR POWER SUPPLY CIRCUIT
Voltage: Approximately 5V OK or NG |
GO TO 3. | Repair open circuit or short to ground or short to power in harness or connectors. |
| 3 | CHECK PSP SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
OK or NG |
GO TO 4. | Repair open circuit or short to ground or short to power in harness or connectors. |
| 4 | CHECK PSP SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
OK or NG |
GO TO 5. | Repair open circuit or short to ground or short to power in harness or connectors. |
| 5 | CHECK PSP SENSOR Refer to [P0550 PSP SENSOR ]. OK or NG |
GO TO 6. | Replace PSP sensor. |
| 6 | CHECK INTERMITTENT INCIDENT Refer to [SERVICE INFORMATION FOR ELECTRICAL INCIDENT: INTERMITTENT INCIDENT ] |
INSPECTION END |