Main Power Window And Door Lock/Unlock Switch Power Supply Circuit Check
DIAGNOSIS PROCEDURE
| Step | Action | YES | NO |
|---|---|---|---|
| 1 | CHECK POWER SUPPLY CIRCUIT
Is the measurement value within the specification? |
GO TO 2 | GO TO 3 |
| 2 | CHECK GROUND CIRCUIT
Is the inspection result normal? |
GO TO 4 | Repair or replace harness. |
| 3 | CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH POWER SUPPLY CIRCUIT
Is the inspection result normal? |
Replace main power window and door lock/unlock switch. Refer to [POWER WINDOW MAIN SWITCH: REMOVAL AND INSTALLATION ]. | Repair or replace harness. |
| 4 | CHECK BCM OUTPUT SIGNAL
Is the measurement value within the specification? |
GO TO 5 | Replace BCM. Refer to [BCM (BODY CONTROL MODULE): REMOVAL AND INSTALLATION ] |
| 5 | CHECK MAIN POWER WINDOW AND DOOR LOCK/UNLOCK SWITCH Check main power window and door lock/unlock switch. Refer to [POWER SUPPLY AND GROUND CIRCUIT CHECK [POWER WINDOW MAIN SWITCH (KING CAB)] ]. Is the inspection result normal? |
Check intermittent incident. Refer to [SERVICE INFORMATION FOR ELECTRICAL INCIDENT: INTERMITTENT INCIDENT ] | Replace main power window and door lock/unlock switch. Refer to [POWER WINDOW MAIN SWITCH: REMOVAL AND INSTALLATION ]. |