Circuit/System Description
A restricted or blocked evaporative emission (EVAP) vent path is detected by the control module commanding the purge valve ON (open) and the vent valve ON (closed) allowing a vacuum to be applied to the EVAP system. Once a calibrated vacuum level has been reached, the control module commands the purge valve OFF (closed) and the vent valve OFF (open) while monitoring the fuel tank pressure (FTP) sensor for a decrease in vacuum.
The following table illustrates the relationship between the ON and OFF states, and the OPEN or CLOSED states of the EVAP canister purge and vent valves.
EVAP CANISTER PURGE VALVE AND EVAP CANISTER VENT VALVE POSITION
| Control Module Command | EVAP Canister Purge Valve | EVAP Canister Vent Valve |
|---|---|---|
| ON | Open | Closed |
| OFF | Closed | Open |