Ambient/Inside Air Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the appropriate temperature sensor.
- Test for less than 1 ohm of resistance between the low reference circuit terminal B and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify the appropriate scan tool Temp Sensor Voltage parameter is greater than 4.9 volts or 250 counts.
- If less than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3 -amp fused jumper wire between the signal circuit terminal A and the low reference circuit terminal B. Verify the scan tool Temp Sensor Voltage parameter is less than 0.1 volt or 5 counts.
- If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the appropriate temp sensor.