Circuit/System Testing
- Remove the fuel fill cap. Connect the GE-41415-50 to the fuel tank filler neck. Connect the J 41413- 200 to the GE-41415-50.
- Seal the system using the Purge Seal function with a scan tool.
- Pressurize the EVAP system with nitrogen to 5 inches H20. Compare the Fuel Tank Pressure Sensor parameter to the J 41413-200 pressure/vacuum gage. The FTP sensor should be within 1 inch H20 of the pressure/vacuum gage.
- If the FTP is not within 1 inch H20 of the pressure/vacuum gage, replace the FTP sensor.
- Command the vent solenoid valve OPEN with a scan tool.
- If the FTP sensor parameter is not 0 inch H20, replace the FTP sensor.